T9000 Series High Performance Vector Control Inverter
Product Introduction
- Open-loop vector control, V/F control, Closed-loop vector control (requires installation of PG card and is applicable for power exceeding 3.7KW).In the closed-loop vector control mode, the speed stability accuracy reaches 0.02%, while in the open-loop vector control mode, it is 0.5%. This can meet the requirements of high-precision processing scenarios.
- Supports EtherCat communication, Profinet communication, CANopen communication and Modbus communication (Except for Modbus, only applicable for 7.5KW and above)
-7.5KW and above models support LCD pull-out keypad, and LED pull-out keypad is fully supported.
- Below 5.5KW (including) support rail mounting and wall mounting;
7.5KW (including) -160KW (including) support wall-mounting;
Above 185KW (including) support floor mounting and wall mounting.
- It supports the STO function. In dangerous or abnormal situations, it prevents the motor from rotating unexpectedly by cutting off the motor's torque output, thereby protecting personnel safety and preventing equipment from damage.
-It integrates many protection functions such as overvoltage, undervoltage, overcurrent, and overheating.
-220V 0.4-7.5KW 380V 0.4-450KW
Technical characteristics
| Item | Specification |
| Control mode | V/F Control, Open-loop Vector Control (without PG), Closed-loop Vector Control (with PG) (for motors above 3.7kW) |
| Maximum Frequency | 0-600HZ |
| Carrier frequency | 0.5 kHz ~ 8 kHz; the carrier frequency can be automatically adjusted according to the load characteristics. |
| Input Frequency Resolution | Digital setting: 0.01 Hz;Analog setting: max. frequency × 0.025% |
| Starting torque | Type G: 0.5 Hz/150% (without PG); Type P: 0.5 Hz/100% |
| Speed control range | 1:200 (no PG) 1:1000(have PG) |
| Speed stability accuracy | ±0.5%(no PG) ±0.02%(have PG) |
| Overload capacity | Type G: 150% rated current for 60s; 180% rated current for 3s.Type P: 120% rated current for 60s; 150% rated current for 3s. |
| Torque boost | Auto torque boost; Manual torque boost 0.1%~30.0% |
| V/F curve | Three modes: Linear type; Multi-point type; N-th power V/F curve(1.2th, 1.4th, 1.6th, 1.8th, 2nd power) |
| V/F separation | 2 modes: Full separation, Semi-separation |
| Acceleration/deceleration curve | Linear or S-curve acceleration/deceleration mode.Four sets of acceleration/deceleration times, acceleration/deceleration time range: 0.0~6500.0s |
| DC braking frequency | DC braking frequency: 0.00 Hz ~ maximum frequency Braking time: 0.0 s ~ 36.0 s Braking current: 0.0% ~ 100.0% |
| Jog frequency | Jog frequency range: 0.00 Hz ~ 50.00 Hz.Jog acceleration/deceleration time: 0.0 s ~ 6500.0 s. |
| Simple PLC;Multi-step speed operation | Up to 16-step speed operation via built-in PLC or control terminals. |
| PID build-in | Easy to implement closed-loop process control system. |
| Automatic Voltage Regulator (AVR) | Automatically maintains constant output voltage when the mains voltage fluctuates |
| Overvoltage & Overcurrent Stall Control | Automatically limits current and voltage during operation to prevent frequent tripping caused by over current and over voltage. |
| Fast current limiting function | Maximally reduces over current faults and ensures the inverter operates normally. |
| Torque Limit and Control | 'Excavator' characteristic: automatically limits torque during operation to prevent frequent over current tripping;torque control can be implemented in closed-loop vector mode. |
| Excellent Performance | Controls asynchronous motors with high-performance current vector control technology. |
| Instantaneous power failure ride-through | During an instantaneous power failure, the voltage drop is compensated by the energy fed back from the load, enabling the inverter to continue operating for a short time. |
| Fast Current Limiting | Avoid frequent overcurrent faults of the inverter. |
| Communication method | RS485 |
| Command Source | Operator panel setting, control terminal setting, serial communication port setting.Switchable via multiple modes. |
| Frequency Source | 10 frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, serial port setting.Switchable via multiple modes. |
| Auxiliary Frequency Source | 10 auxiliary frequency sources.Flexibly realize auxiliary frequency fine-tuning and frequency synthesis. |
| Input Terminal | Standard: 5 digital input terminals (1PH 220V 0.4kW–3.7kW / 3PH 380V 0.75kW–5.5kW) / 6 digital input terminals (above 7.5kW), among which S3 supports high-speed pulse input up to 100kHz; 1 analog input terminal (below 5.5kW) / 2 analog input terminals (above 7.5kW), with 1 channel supporting 0–10V voltage input and 1 channel supporting 0–10V voltage input or 4–20mA current input. |
| Output Terminals | 1 high-speed pulse output and collector output terminal.1 relay output terminal (below 5.5kW) / 2 relay output terminals (above 7.5kW).1 analog output terminal (1PH 220V 0.4kW–3.7kW / 3PH 380V 0.75kW–5.5kW) / 2 analog output terminals (above 7.5kW), supporting 4–20mA current output or 0–10V voltage output. |
| LED Display | Display Parameters |
| Key Lock & Function Selection | Lock part or all of the keys and define the function range of some keys to prevent misoperation. |
| Protection Functions | Power-on motor short-circuit detection, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc. |
| Operating Environment | Indoor, free from direct sunlight, dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water or salt, etc. |
| Altitude | Below 1000m |
Application
T9000 series vfd can be widely used in small and medium power applications, such as food machinery, plastic machinery, ceramic equipment, petroleum machinery, cable equipment, air compressors, CNC, woodworking machinery, textile machinery, printing and packaging equipment, chemical equipment, environmental protection equipment, Conveying equipment, etc.
Copyright © Copyright:ZONCN Record number:1943255 sitemap(Baidu / Google)
Technical SupportJinfeng Operations 统计代码放置
administrator
There are currently no comments on this content