Hello! Welcom Whzoncn Website!
中文版

CASE

PRODUCT

Z2000 Series

Release time:2026-02-024982 times viewed
Z2000 Series Compact Vector Control Inverter

Z2000 Series Compact Vector Control Inverter


Product Introduction

- Open-loop vector control, VF control

- Optional built-in EMC filter, supports MODBUS RS485 communication, supports MODBUS RTU, and optional EtherCAT communication;

- Support permanent magnet synchronous motors;

- It has an overload capacity of 150% of rated current for a continuous 60 seconds and 180% of rated current for a continuous 3 seconds, and can handle frequent impact loads;

- Phase loss protection, overheat protection, overvoltage protection and other protection functions;

- Supports 220V input and 380V output; supports 110V; supports 380V; supports 440V; supports 480V;

- 0.4 - 37KW with built-in braking unit; 45 - 160KW with optional built-in braking unit;For power ratings above 22KW, an internal DC reactor is optional. This can help mitigate the impact of unstable voltage;

- NPN supported, PNP optional;Support detachable LED keyboard;

- High torque output ensures smooth startup of the motor during heavy loads;

- ZONCN independently developed IGBTs, with excellent performance;Power range: 220V 0.4 - 7.5KW 380V: 0.4 - 450KW;


Technical characteristics 

ItemSpecification
The highest frequency

Vector control: 0 - 320 Hz

V/F control: 0 - 3200 Hz

Carrier frequency

0.5 kHz to 16 kHz

The carrier frequency can be automatically adjusted according to the load characteristics.

Input frequency resolution

Digital setting: 0.01Hz

Analog setting: Maximum frequency × 0.025%

Control method

Open-loop vector control (without PG)

V/F control

Starting torque

G model: 0.5Hz/150% (without PG);

P model: 0.5Hz/100%

Speed regulation range1:100 (without PG)
Steady speed accuracy±0.5% (without PG)
Torque control accuracy±5%(FVC)
Overload capacityG-type inverter: 150% of rated current for 60s; 180% of rated current for 3s.P-type inverter: 120% of rated current for 60s; 150% of rated current for 3s.
Torque increaseAutomatic torque increase; Manual torque increase: 0.1% to 30.0%
VF curveThree modes: Linear type; Multi-point type; N-th power V/F curve (1.2th, 1.4th, 1.6th, 1.8th, 2nd power)
VF separationTwo methods: Complete separation, Partial separation
Acceleration and deceleration curve

Linear or S-curve acceleration/deceleration mode.

Four sets of acceleration/deceleration times.

Acceleration/deceleration time range: 0.0 ~ 6500.0 s

DC braking

DC braking frequency: 0.00 Hz ~ maximum frequency

Braking time: 0.0 s ~ 100.0 s

Braking current: 0.0% ~ 100.0%

Jog control

Jog frequency range: 0.00 Hz ~ 50.00 Hz.

Jog acceleration/deceleration time: 0.0 s ~ 6500.0 s.

Simple PLC, multi-speed mode OperationThrough the built-in PLC or control terminals, up to 16 speed runs can be achieved.
Build-in PIDIt can conveniently realize the closed-loop control system for process control.
Automatic Voltage Regulation (AVR)When the grid voltage changes, it can automatically maintain the output voltage constant.
Overvoltage and overcurrent speed controlAutomatically limits current and voltage during operation to prevent frequent overcurrent and overvoltage tripping.
Fast current-limiting functionMinimize overcurrent faults to ensure the normal operation of the frequency converter
Torque Limitation and Control'Excavator' characteristic: automatically limits torque during operation to prevent frequent overcurrent tripping.
Outstanding performanceUsing high-performance current vector control technology to achieve asynchronous motors
Instant stop, no pause.During an instantaneous power outage, energy is fed back to the load to compensate for the voltage drop, allowing the frequency converter to continue operating for a short period of time.
Fast current limitingPrevent the frequency converter from frequently experiencing overcurrent faults
Timed controlTiming Control Function: Set time range from 0.0Min to 6500.0Min
Communication methods supportRS485;EtherCAT;
Command sourceSet by operation panel, set by control terminals, set by serial communication port.Switchable via multiple modes.
Frequency source

10 frequency sources: digital reference, analog voltage reference, analog current reference, pulse reference, serial port reference.Switchable via multiple modes

Auxiliary frequency source10 types of auxiliary frequency sources. They can be flexibly used for auxiliary frequency fine-tuning and frequency synthesis.
Input terminal

Standard: 6 digital input terminals, 1 of which supports high-speed pulse input up to 100 kHz (S3 optional);

2 analog input terminals: 1 supports only 0–10 V voltage input (FIV), 1 supports 0–10 V voltage input or 4–20 mA current input (FIC).

Output terminal

Standard:

1 digital output terminal (MO1)

1 relay output terminal (RA, RB, RC)

1 analog output terminal, supporting 0~20 mA current output or 0~10 V voltage output (FOV)

LED displayDisplay parameters
Key lock and function selectionImplement partial or complete locking of the buttons, define the action scope of some buttons to prevent accidental operation
Protection functionPower-on motor short-circuit detection, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, overload protection


Product application

It has been widely applied in fields such as air compressors, food processing machinery, rubber production equipment, textile machinery, machine tools, water pumps, spindle motors, etc. For example, in the building materials industry, it cooperates with the multi-speed function to achieve precise temperature control of kilns; in hoisting equipment, it relies on the high dynamic response of vector control to avoid the risk of hook slipping.

What do you think of this article?

0 0
netizen comments

administrator

There are currently no comments on this content

局域网net friend
Service Hotline

Service Hotline

0086-553-2619975

Whatsapp Contact
ZONCN
Back to top